Introduction
BIX-8802 is a spectrum analysis apparatus designed for physics, chemistry, biology, environment labs and scientific research in university and college. It also can be used for industrial spectrum testing. This apparatus can analyze emitting spectrum, transmission spectrum and reflection spectrum. It’s modular designed with simple structure and flexible configuration.
Feature
● Modular designed with flexible configuration
● Can be used to measure spectrum of light source, solid or liquid material’s transmission spectrum and reflection spectrum
● Wavelength can be chosen from 200nm to 1100nm
● Customized products is available
Emitting Spectrum
The light couples into the spectrometer through the optical fiber directly so that the spectral data of the light source can be obtained.
Applications:
● Spectrum of laser
● Spectrum of LED
● Spectrum of sunlight
● Spectrum of other light source
Standard Hg lamp
Order Information
No |
Description |
Model# |
Qty. |
Notes |
1 |
FiberSpectrometerWavelength 200nm-1100nmOptical resolution 0.1nm-1nm |
BIM-60/BIM-66 series |
1 |
Determined by the wavelength and resolution |
2 |
Quartz Optical, L1.5m, Φ600μm |
BIM-6102 |
2 |
- |
Liquid samples transmissuon spectrum
Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve and absorptivity curve by the software.
Applications
The component analysis and concentration measurement of chemicals, food or water.
Reference spectrum Transmission spectrum of CuSO4 solution
Order Information
No |
Description |
Model# |
Qty. |
Notes |
1 |
Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm |
BIM-60/BIM-66 series |
1 |
Determined by the wavelength and resolution |
2 |
Quartz Optical, L1.5m, Φ600μm |
BIM-6102 |
2 |
- |
3 |
Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W |
BIM-6202 |
1 |
- |
4 |
10dB Attenuator |
BIM-7921 |
1 |
- |
5 |
Cuvette mount |
BIM-6305 |
1 |
- |
6 |
Plastic Cuvette, 12.5 mm×12.5 mm×45 mm, (6EA) |
BIM-6301 |
1 |
- |
7 |
Samples |
- |
- |
User-supplied |
Solid samples transmission analysis
Using the spectrometer to measure the tungsten as reference spectrum, it can measure the sample’s transmission spectrum. Then you can get the transmissivity curve by the software.
Reference spectrum Transmission spectrum of filter
Applications
● The transmissivity, central wavelength and bandwidth of optical filter, sunglasses or car window films
● Component analysis of solid samples
Order Information
No |
Description |
Model# |
Qty. |
Notes |
1 |
Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm |
BIM-60/BIM-66 series |
1 |
Determined by the wavelength and resolution |
2 |
Quartz Optical, L1.5m, Φ600μm |
BIM-6102 |
2 |
- |
3 |
Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W |
BIM-6202 |
1 |
- |
4 |
10dB Attenuator |
BIM-7921 |
1 |
- |
5 |
Cuvette mount |
BIM-6305 |
1 |
- |
6 |
Samples |
- |
- |
User-supplied |
Solid samples reflection analysis
Using the spectrometer to measure the tungsten as reference spectrum, and then measure the sample’s reflection spectrum. The reflectance curve will be got by software.
Reference spectrum Reflection spectrum of red paper
Applications
● Component analysis of solid samples
● Color measurement of paper, textile or oil paint (Developing)
Order Information
No |
Description |
Model# |
Qty. |
Notes |
1 |
Fiber Spectrometer, Wavelength 200nm-1100nm, Optical resolution 0.1nm-1nm |
BIM-60/BIM-66 series |
1 |
Determined by the wavelength and resolution |
2 |
Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm |
BIM-6103 |
2 |
- |
3 |
Tungsten Light SourceⅡ, with the focusing lens, 400nm-2000nm, 10W |
BIM-6202 |
1 |
- |
4 |
Double Channels Reflection Mount Φ150mm×13mm |
BIM-6303 |
1 |
- |
5 |
Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm) |
BIM-6304 |
1 |
- |
6 |
Samples |
- |
- |
User-supplied |
Specification
Description |
Model# |
Parameters |
Fiber Spectrometer |
BIM-60/BIM-66 series |
Please see Fiber Spectrometer's introduce |
Quartz Optical |
BIM-6102 |
L1.5m, Φ600μm |
Tungsten Light Source |
BIM-6202 |
With the focusing lens, 400nm-2000nm, 10W; Maximum voltage: 12V DC; 2000 hours; SMA905 connector; Dimension: 100mm × 60mm × 34.5mm; 0.2Kg |
Cuvette mount |
BIM-6305 |
140mm*140mm*40mm |
Plastic Cuvette |
BIM-6301 |
6EA, 12.5 mm×12.5 mm×45 mm |
SolidSample Transmission Mount |
BIM-6302 |
200mm*78mm |
Double Channels Reflection Mount |
BIM-6303 |
Φ150mm×13mm |
Diffuse Reflectance Standard |
BIM-6304 |
Φ40mm, R97% (350nm-2000nm) |
Reflection Quartz Fiber |
BIM-6103 |
Single Core, L 1.5m, Φ600μm |
Parts List
No . |
Description |
Moel# |
Qty . |
1 |
Fiber Spectrometer,Wavelength 200nm-1100nm,Optical resolution 0.1nm-1nm |
BIM-60/BIM-66 series |
1 |
2 |
Quartz Optical, L1.5m, Φ600μm |
BIM-6102 |
1 |
3 |
Reflection Quartz Fiber (Single Core), L 1.5m, Φ600μm |
BIM-6103 |
2 |
4 |
Tungsten Light SourceⅡ, with the focusing lens,400nm-2000nm, 10W |
BIM-6202 |
1 |
5 |
10dB Attenuator |
BIM-7921 |
1 |
6 |
Plastic Cuvette, 12.5 mm×12.5 mm×45 mm,(6EA) |
BIM-6301 |
1 |
7 |
Solid Sample Transmission Mount, L300mm |
BIM-6302 |
1 |
8 |
Double Channels Reflection Mount Φ150mm×13mm |
BIM-6303 |
1 |
9 |
Diffuse Reflectance Standard,Φ40mm, R97% (350nm-2000nm) |
BIM-6304 |
1 |
10 |
Cuvette mount |
BIM-6305 |
1 |